Search CDS

 
 Currently in: Support>Software Support>Installation Guide>Upgrade Guide

 
Upgrading to versions

Installing

  • After receiving a link to download, double pick the EXE .
  • Software will be installed in a new directory.
  • This will NOT upgrade previous version installations.
  • Follow the prompts or refer to the Installation guide on our website for detailed install instructions.
  • Once the software installation has completed, you must have a new CDS.PWD license file (See Licensing below).
  • Once you have a new license file, run the software from the Start menu in the CAD Design Software program group.
  • Any previous version will still be accessible by running from the Start menu.
  • You may point the new install of EPD to your existing Library files or copy them (See Library Files below).
  • Any previous versions can be uninstalled to free up hard drive space or can remain installed.
  • Customers using the network version will have to use the same procedure except the license will need to be re-read on the license server (See Licensing below).

           

Licensing

  • Unit and Dongle Licenses  

    • Previous versions of EPD (7.0-7.5) will work with a license as long as the version in the license is higher than the version you are running. If you want to run EPD 7.4 and currently have a 7.2 license file, it will not work.
    • There should only be ONE (1) CDS.PWD license file on a computer.  

  • Network License  
  • Place CDS.PWD in the \CDSFlexLM directory and overwrite the older file.
  • Run the lmtools.exe.
  • Pick the Configure using Services radio button.
  • Select the Service to edit (CAD DESIGN SOFTWARE).
  • Located along the top of the LMTOOLS dialog box, pick the Start/Stop/Reread tab.
  • Pick the Stop Server button.
  • Pick the ReRead License File button. (May say Reread Server Failed).
  • Pick the Start Server button.
  • Pick the Server Status tab.
  • Pick the Perform Status Enquiry button.
  • Scroll down to the line Vendor daemon status (on server).
  • Verify it says:
  • CDS:  UP vX.X

Library Files
  • These files are in a default location of
    • \EPD\HYB\, \EPD\PCB\, \EPD\SCH\, \EPD\ASY\Data, \EPD\Fab\Data

  • We always recommend that when using EPD components, you save them as a different name and not overwrite existing EPD data files.
  • Typically, custom design library files would not be saved in any of these directories.
  • New folders or sub-folders would be created (either in EPD, on a network drive or other location of the computer).
  • Browse these directories if you are not sure and check the date stamps on the files.

  • \HYB
    • The default folders that come with EPD’s installation are the following:
    • \CUSTOM
    • \DATA
    • \SLIDES
    • \STACKED

 

  • \PCB
    • The default folders that come with EPD’s installation are the following:
    • \DATA
    • \SLIDES
    • \TECH

 

  • \SCH 
    • The default folders that come with EPD’s installation are the following:
    • \BASIC
    • \CUSTOM
    • \GATES
    • The SCH.DAT and LIB.DB files should be copied from the SCH directory.

  • \ASY
    • The default folders that come with EPD’s installation are the following:
    • \Data
  • \FAB
    • The default folders that come with EPD’s installation are the following:
    • \Data

 

 Home | Software | Company | Demos | Sales | News | Support | Search | Contact

Policy Statement
Website Copyright © CAD Design Services Inc. All rights reserved. 
CAD Design Software is a division of CAD Design Services Inc.